The department maintains the list below of TNI that have been listed for use in Indiana. Where applicable, a link for each technology is provided to the department standards for that technology. These standards are the basis for plan review, construction approvals, training, design and installation, and operation and maintenance (O&M), if applicable.
Information is grouped under four technology categories: "Components," "Secondary Treatment Units," "Soil Absorption Fields," and "Pretreatment Devices,"
Each listing includes the following:
Onsite system components are evaluated on a case-by-case basis. Components may include distribution boxes, distribution devices, siphons, pressure manifolds, etc.
Fluid Dynamic Siphons, Inc.
P.O. Box 88219
Steamboat Springs, CO 80488-2019
Web site: http://www.siphons.com/
| Technology: | Siphons. |
|---|---|
| Status: | Project-by-project approval. |
| Description: | Automatic dosing siphons for small flood dose systems, typically used in place of a pump on sites where electricity is not available. |
Zoeller Company
3649 Cane Run Rd
Louisville, KY 40211-1961
Mr. Adrian France
Phone: (502) 778-2731
Fax: (502) 774-3624
Email: adrianf@zoeller.com
Web site: http://www.zoeller.com/
| Technology: | Tru-Flow Splitter |
|---|---|
| Status: | Approved |
| Date: | 5/22/2006 |
| Description: | D-box of molded polypropylene with two parts: housing (basin/cover) and diverter. Bubble level allows for post installation adjustments to equalize flow to five lines. |
| Comments | SEE STANDARD FOR ALL CONDITIONS: Subsurface gravity trench systems only; must be installed according to Zoeller installation requirements. |
| Link to Standards | Standards |
The use of secondary treatment systems in Indiana must comply with the requirements in the Indiana Standards for Secondary Treatment Systems. Secondary treatment systems are reviewed by the department after submittal by a manufacturer or system integrator (SI).
To be listed, the manufacturer of a secondary treatment system must have on file with the department an application and documentation for review against the requirements of Indiana Standards for Secondary Treatment Systems. Such listing will have the status either “Project-by-project approval” or “Approved” A status of “Project-by-project approval” means that the department may approve the use of the technology on a case by case basis for individual projects under the parameters of Indiana Standards for Secondary Treatment Systems. But until a general approval is issued, each individual project must be reviewed by the department. When the department has finished a satisfactory review of the technology, the status will be changed from “project-by-project approval” to “Approved.” At that time, local health departments may issue permits for the use of that technology, provided such approvals meet all of the requirements of the standards for that technology as well as all of the requirements of 410 IAC 6-8.3.
For the repair, remediation or replacement of an existing residential onsite soil absorption field, the use of a secondary treatment unit must comply with the applicable requirements of 410 IAC 6-8.3.
Aerotech
2900 Gary Drive
Plymouth, IN 46563
Website: www.aerotech-atu.com
Mr. Dan Papczynski
Phone: 574-935-0908
Fax: 574-935-0910
Email: dan_pap@embarqmail.com
| Technology: | Model AT-500; 500 G.P.D. Model AT-600; 600 G.P.D. Model AT-750; 750 G.P.D. Model AT-1000; 1000 G.P.D. Model AT-1500; 1500 G.P.D. |
|---|---|
| Status: | Approved |
| Description: | Fiberglass and polyethylene tanks using an extended aeration, activated sludge process. |
| Comments: | SEE APPROVAL FOR ALL CONDITIONS |
| Link to Approval: | Approval Letter |
BioMicrobics
8450 Cole Parkway
Shawnee, KS 66227 USA
Website: www.biomicrobics.com
Allison Blodig, REHS
Manager, Regulatory Affairs & Special Projects
Phone: (913)422-0707
Fax: (913)422-0808
| Technology: | MicroFAST 0.5, 500 gpd MicroFAST 0.75, 750 gpd MicroFAST 0.90, 900 gpd MicroFAST 1.50, 1500 gpd |
|---|---|
| Status: | Project-by-project approval |
| Description: | A polyethylene aeration insert into a concrete tank using a fixed film extended aeration, activated sludge process. |
Jet, Inc.
750 Alpha Drive
Cleveland, OH 44143
Website: www.jetincorp.com
Chris Mandich
National Sales Representative
Phone: (216) 538-8805
Email: cmandich@jetincorp.com
| Technology: | J-500, 500 gpd J-750, 750 gpd J-1000, 1000 gpd J-1250, 1250 gpd J-1500, 1500 gpd J-500-PLT, 500 J-800-PLT, 800 |
|---|---|
| Status: | Project-by-project approval |
| Description: | Concrete or plastic tanks using a fixed film extended aeration, activated sludge process. |
Norweco
220 Republic Street
Norwalk, OH 44857
Website: http://www.norweco.com/
Scott Hetrick
Sales Manager
Phone: (419)668-4471
Email: shetrick@norweco.com
| Technology: | Model 960-500, 500 gpd Model 960-600, 600 gpd Model 960-750, 750 gpd Model 960- 1,000, 1,000 gpd Model 960-1,250, 1,250 gpd Model 960-1,500, 1,500 gpd Model 960 LP-500, 500 gpd Model 960 LP-1000, 1,000 gpd Green 960-500, 500 gpd Green 960-600, 600 gpd |
|---|---|
| Status: | Approved |
| Date: | 07/31/2012 |
| Description: | Concrete or polyethylene tanks using extended aeration, activated sludge process. |
| Comments: | SEE APPROVAL LETTER FOR ALL CONDITIONS |
| Link to Approvals: | Approval Letter Approval Letter |
Quanics, Inc
244 Old LaGrange Road
P.O. Box 1520
Crestwood, KY 40014
Website: www.quanics.net
Kevin Sherman
Phone: 502) 992-8215
Email: osmc2001@yahoo.com
| Technology: | AeroCell BioCoir |
|---|---|
| Status: | Project-by-project approval |
| Date: | 07/31/2012 |
| Description: | Aerocell is a recirculating treatment system using open cell foam media. BioCoir is a recirculating treatment system using recycled husks of coconuts. Both use fiberglass tanks. |
Zoeller Company
3649 Cane Run Rd
Louisville, KY 40211-1961
Mr. Adrian France
Phone: (502) 778-2731
Fax: (502) 774-3624
Email: adrianf@zoeller.com
Web site: http://www.zoeller.com/
| Technology: | Recirculating Gravel Filter. |
|---|---|
| Status: | Project-by-project approval |
| Description: | Recirculating gravel filter with a bed of gravel to treat effluent with organisms that live on the media (80% of effluent is recirculated for additional treatment). Numerous sizes are available to accommodate a range of loading and site requirements. |
| Technology: | Z-Cell Wetland |
|---|---|
| Status: | Project-by-project approval. |
| Description: | The Z-Cell is a constructed wetland that manages the inflow of effluent using time dosing and uniform application to the bottom of the treatment cell. Effluent moves vertically through the horizontally-oriented plant root zone to provide treatment. |
The department has general standards for some soil absorption field TNI. Other technologies are evaluated on a case-by-case basis. The use of these technologies in Indiana must comply with the requirements in the standards or approval. Soil absorption field technology for which the department has established general standards include:
Advanced Drainage Systems, Inc.
3300 Riverside Drive, P.O. Box 21307
Columbus, OH 43221
Mr. Dick Bachelder
Phone: (800) 821-6710
Web site: http://www.ads-pipe.com/
| Technology: | GEO-flow Pipe Leaching System |
|---|---|
| Status: | Approved |
| Date: | 08/30/2012 |
| Description: | Corrugated, perforated, high density pipe with a thick mat of plastic fibers and plastic geotextile material surrounding the pipe installed in a sand bed. |
| Comments | SEE APPROVAL LETTER FOR ALL CONDITIONS: design and installation must comply with the ADS-Geoflow manual; designers, installers and LHD staff must be trained and certified. |
| Link to Approval Letter & Standards | Approval Letter Standards |
| Technology: | Gravelless Pipe Technology |
|---|---|
| Status: | Approved |
| Date: | 11/28/1988 |
| Description: | 8" & 10" corrugated polyethylene plastic pipe with 3/8" or 1/2" diameter holes located 120 degrees from the top centerline and wrapped with Cariff non-woven polyester geotextile fabric. |
| Comments | SEE APPROVAL LETTER FOR ALL CONDITIONS: install in gravity trenches only; SAF size: 1 Lf of 10" dia. pipe in great. or eq. to 20" trench corr. to 1 Lf of 3' wide trench; 1 Lf of 8" dia. pipe in great. or eq. to 16" trench corr. to 1 Lf of 2' wide trench. |
| Link to Approval | Approval Letter |
Baughman Tile Company
8516 Township Road
Paulding, OH 45879
Lorie Thornell
| Technology: | Gravelless Pipe Technology |
|---|---|
| Status: | Approved |
| Date: | 8/6/2002 |
| Description: | 8" & 10" corrugated polyethylene plastic pipe with 3/8" or 1/2" diameter holes located 120 degrees from the top centerline and wrapped with Cariff non-woven polyester geotextile fabric. |
| Comments | SEE APPROVAL LETTER FOR ALL CONDITIONS: install in gravity trenches only; SAF size: 1 Lf of 10" dia. pipe in great. or eq. to 20" trench corr. to 1 Lf of 3' wide trench; 1 Lf of 8" dia. pipe in great. or eq. to 16" trench corr. to 1 Lf of 2' wide trench. |
| Link to Approval | Approval Letter |
Eljen Corporation
125 McKee Street
East Hartford, CT 06108
Mr. James Donlin
Phone: (800) 444-1359
Fax: (860) 610-0427
Email: JMDEljen@cs.com
Web site: http://www.eljen.com/
| Technology: | GSF (Geotextile Sand Filter) |
|---|---|
| Status: | Approved |
| Date: | 1/28/2010 |
| Description: | Cuspated plastic core units [48" x 36" x 7" (L x W x H) and 24" x 36" x 7" (L x W x H)], Bio-Matt™ filter fabric internal to the unit, and geotextile fabric covering the unit, installed in a trench SAF. |
| Comments | SEE STANDARD FOR ALL CONDITIONS: design and installation must comply with Eljen manual, December, 2010 |
| Link to Approval Letter & Standards | Approval Letter Standards |
Francesville Drainage Tile Corp.
P.O. Box 368
Francesville, IN 47946-0368
Mr. Christopher S. Overmyer
| Technology: | Gravelless Pipe Technology |
|---|---|
| Status: | Conditional approval |
| Date: | 6/27/2002 |
| Description: | 10" corrugated polyethylene plastic pipe with 3/8" diameter holes located 120 degrees from the top centerline and wrapped with Cariff non-woven polyester geotextile fabric. |
| Comments | SEE APPROVAL LETTER FOR ALL CONDITIONS: install in gravity trenches only; SAF size: 1 Lf of 10" dia. pipe in great. or eq. to 20" trench corr. to 1 Lf of 3' wide trench. |
| Link to Approval | Approval Letter |
Haviland Drainage Products Company
P.O. Box 97, 100 West Main Street
Haviland, OH 45851
Mr. Douglas A. Wenninger
Phone: (419) 622-4611
| Technology: | Graveless Pipe Technology, LPS 56/S |
|---|---|
| Status: | Approved |
| Date: | 7/3/2002 |
| Description: | LPS 56/S (low profile) gravelless system: 5 corrugated perforated pipes, each with outside diameter of 7.125 inches in 36 inch wide SAF trenches, with geotextile fabric, in lieu of aggregate. |
| Comments | SEE APPROVAL LETTER FOR ALL CONDITIONS: install in gravity trenches only; pipe must meet AASHTO M-252 Type SP; no size reduction. |
| Link to Approval | Approval Letter |
Infiltrator Systems, Inc.
4 Business Park Road
P.O. Box 768
Old Saybrook, CT 06475
Mr. David Lentz, P.E.
Phone: (860)577-7198
Email: dlentz@infiltratorsystems.net
Website: www.infiltratorsystems.com
| Technology: | Chamber |
|---|---|
| Status: | Approved |
| Date: | 1/6/2006 |
| Description: | Approved chamber products: Arc 24; Arc 36; Arc 36LP; BioDiffuser; Standard Bio 3 (22” wide); Quick4 Equalizer 36 (22” wide); Quick4 Standard & Quick4 Standard W; Quick4 Plus Standard; Quick4 Plus Standard Low Profile (LP). |
| Comments | SEE STANDARD FOR ALL CONDITIONS: Subsurface trench system only; H-10 load rating; up to 25% size reduction; reduction may not be combined with size reduction allowed for STUs. |
| Link to Standards | Standards |
| Technology: | EZFlow by Infiltrator |
|---|---|
| Status: | Approved |
| Date: | 1/26/2012 |
| Description: | Approved product: EZFlow EZ1203H. Synthetic aggregate product using expanded polystyrene (EPS) aggregate held together in cylindrical bundles with high strength polyethylene netting. |
| Comments | SEE STANDARD FOR ALL CONDITIONS: subsurface trench systems only; design and installation must comply with EZFlow manual and applicable department rules and standards. |
| Link to Approval Letter & Standards | Approval Letter Standards |
Presby Environmental, Inc.
143 Airport Road
Whitefield, NH 03598
Mr. David Presby
Phone: (800) 473-5298
Fax: (603) 837-9864
Email: info@presbyeco.com
Web site: http://www.presbyenvironmental.com/
| Technology: | Presby Enviro-Septic (ES) System Presby Advanced Enviro-Septic (AES) System |
|---|---|
| Status: | Approved |
| Date: | 4/6/2011 |
| Description: | ES System: Corrugated, perforated, high density pipe with a thick mat of plastic fibers and plastic geotextile material surrounding the pipe installed in a sand bed. AES System: Corrugated, perforated, high density pipe with a modified thick mat of plastic fibers and plastic geotextile material surrounding the pipe installed in a sand bed. |
| Comments | SEE STANDARDS FOR ALL CONDITIONS: design and installation must comply with Presby manual; designers, installers, and LHD staff must be trained and certified; Presby must notify ISDH of all certified persons and all installations. |
| Link to Standards | ES system AES system |
| Technology: | Presby Simple-Septic (SS) System |
|---|---|
| Status: | Interim Approval |
| Date: | 11/28/2012 |
| Description: | SS System: Corrugated, perforated, high density with a plastic geotextile material surrounding the pipe installed in a sand bed. |
| Comments | SEE APPROVAL LETTER FOR ALL CONDITIONS: design and installation must comply with Presby manual; designers, installers, and LHD staff must be trained and certified; Presby must notify ISDH of all certified persons and all installations. |
| Link to Approval Letter | Approval Letter |
Prinsco, Inc.
P.O. Box 287, 108 Highway 7 West
Prinsburg, MN 56281-0265
Mr. James Duininck
| Technology: | Gravelless Pipe Technology |
|---|---|
| Status: | Approved |
| Date: | 6/3/2002 |
| Description: | Prinsco GLP Sock Pipe: 8" & 10" corrugated polyethylene plastic pipe with 3/8" or 1/2" diameter holes located 120 degrees from the top centerline and wrapped with GLP non-woven polypropylene geotextile fabric. |
| Comments | SEE APPROVAL LETTER FOR ALL CONDITIONS: install in gravity trenches only; SAF size: 1 Lf of 10" dia. pipe in great. or eq. to 20" trench corr. to 1 Lf of 3' wide trench; 1 Lf of 8" dia. pipe in great. or eq. to 16" trench corr. to 1 Lf of 2' wide trench. |
| Link to Approval | Approval Letter |
Pretreatment devices are typically installed upstream of the septic tank in an onsite system and are evaluated on a case-by-case basis.
Algaewheel, Inc.
1426 West 29th Street, Suite 206
Indianapolis, IN 46208
Mr. Chris Limcaco
Phone: (317) 989-2001
Fax: (317) 829-5902
Email: info@algaewheel.com
Web site: http://www.algaewheel.com/
| Technology: | BacPac Unit |
|---|---|
| Status: | Conditional approval |
| Date: | 3/10/2006 |
| Description: | Single pass pretreatment system in which algal colonies provide treatment and filtration. |
| Comments | SEE APPROVAL LETTER FOR ALL CONDITIONS: max. of 50 units (residential & commercial); pretreatment only; unit must be followed by septic tank and SAF that comply with 410 IAC 6-8.1 or 410 IAC 6-10. |
| Link to Approval | Approval Letter |